FACILITY

Bacteria Room

The bacteria room provides all the instruments needed for the culture, genetic engineering, selection and expansion of bacteria.

Before using the instruments for the first time, contact the trainers below for mandatory training.
Users are expected to perform experiments independently and must be adequately trained to ensure proper use of the instruments.

How to make reservation

Prior to use, it is mandatory to reserve instruments through the booking platform of the Department of Biomedical Sciences.

If you don’t have an account to access the booking platform, please contact our ICT service staff at ‘informatica.biomed@unipd.it’.

Coordination & Training

Service coordinator

LOPREIATO RAFFAELE

Training & support staff

BERTIN VALERIA
MARCHIONNI IVAN

The Facility’s staff are available Monday to Friday during normal working hours (09:00-16:00).

Where is & How the facility works

Location

Room 6-139 (floor 5N), Vallisneri building
Room 6-138 (floor 5N), Vallisneri building
Room 6-128 (floor 5N), Vallisneri building
Room 6-129 (floor 5N), Vallisneri building

Opening and closing

Monday - Sunday  |  24h


Guidelines

Shakers positions

Fees

For information: bacteriaroom.biomed@unipd.it

Facility equipment

BOOK NOW

Room 6-139 (floor 5N), Vallisneri building

biological hood
BioAir Aura Mini

No manuals available for this instrument.

BOOK NOW

Room 6-139 (floor 5N), Vallisneri building

biological hood
GELAIRE TC 48

No manuals available for this instrument.

BOOK NOW

Room 6-139 (floor 5N), Vallisneri building

shaker
EXCELLA E25
Available Manuals:

BOOK NOW

Room 6-138 (floor 5N), Vallisneri building

shaker
INNOVA 44
Available Manuals:

BOOK NOW

Room 6-129 (floor 5N), Vallisneri building

shaker
KS 501 IKA LABORTECHNIK N°1 (28°C room)

No manuals available for this instrument.

BOOK NOW

Room 6-129 (floor 5N), Vallisneri building

shaker
KS 501 IKA LABORTECHNIK N°2 (28°C room)

No manuals available for this instrument.

BOOK NOW

Room 6-128 (floor 5N), Vallisneri building

shaker
KS125 Basic IKA Labortechnik (37°C room)

No manuals available for this instrument.

BOOK NOW

Room 6-139 (floor 5N), Vallisneri building

shaker
New-Brunswick Scientific C24

No manuals available for this instrument.

BOOK NOW

Room 6-128 (floor 5N), Vallisneri building

shaker
Orbi-shaker Benchmark Vetrotecnica (37°C room)

No manuals available for this instrument.

BOOK NOW

Room 6-128 (floor 5N), Vallisneri building

shaker
Rotating shaker Mod. CLMX F.lli Galli (37°C room)

No manuals available for this instrument.

BOOK NOW

Room 6-128 (floor 5N), Vallisneri building

shaker
T-Shaker EMSC 100 Euroclone (37°C room)

No manuals available for this instrument.

Before your session
  • Wear a lab coat and clean gloves.
  • Equipment must be checked in all their parts: everything must be clean and without any obvious damage. If this is not the case, please immediately contact the staff.
  • CHECK IF YOU ARE THE FIRST USER OF THE DAY AND, IN THIS CASE, TURN ON THE UV LAMP FOR AT LEAST 20 MINUTES. REMEMBER TO TURN OFF THE UV LAMP BEFORE USING THE HOOD!
  • MANDATORY HOOD OPENING PROCEDURE: switch on the hood and the flux; ONLY once the flux is fully operational, the frontal lid can be removed.
  • Spectrophotometer must be switched on 10 minutes before use.
  • For the use of the shakers: each bottle has to be labeled with NAME, LAB, TELEPHONE NUMBER of the owner.
  • Report to the staff the presence of incorrect behavior or waste not properly disposed of.
During your session

Good lab practices must be followed. Perform procedures in a way that minimizes aerosols (opening tubes slowly, pouring liquids without splashing, etc.).

The agar plates have to be labeled with a NAME and can be incubated inside the indicated drawers, in the room at 37°C.


After your session
  • Clean all surfaces first with water and then with 70% ethanol. Please do not use bleach on any work surface.
  • Properly discard solid biological waste into a biological bin of your lab. It can be left inside the room, LABELED WITH A NAME AND OPENING DATE and CLOSE OUT OF YOUR SESSION. Don’t leave open bins for long periods. The collection and conferral to the office of competence remains the RESPONSIBILITY OF THE PRODUCER.
  • All liquid biological waste must be bleached (1:10) and DISCARDED IN YOUR OWN LAB.
  • DO NOT leave anything in the room (out of your assigned space in the shelf) and inside the hoods and thermoshakers.
  • Switch off the spectrophotometer after each use, to prevent deterioration of the light source.
  • Switch off thermoshakers and check if the surfaces and positions are clean. If not, it must be cleaned first with water and then with 70% ethanol or denatured alcohol.
  • Switch off the centrifuge after each use.
  • MANDATORY HOOD CLOSING PROCEDURE: the frontal lid must be positioned back in place BEFORE switching off the flux; ONLY once the hood is properly closed, switch off the flux. Switch off the light and THEN the hood.
  • Contaminated gloves must be discarded.

Specific indication for this facility

  • For shakers Excella E25, Innova 44, New Brunswick Scientific C24, Orbi-shaker Benchmark and Ika Labortechnik KS 125 BASIC bottle positions are identified with a code and need to be BOOKED INDIVIDUALLY. The letter of the code indicates the size of the position (XS/S/M/L/XL). Please use the code of the booked positions.
  • As different cultures could need different temperatures of incubation, in case of more reservations at the same time THE TEMPERATURE OF THE SHAKER IS DEFINED BY THE FIRST USER BOOKED, that will specify the protocol in use in the description field (temperature and RPM in use).
  • The same user can’t book multiple shakers at the same time, to allow everyone to use them.
  • It is forbidden to put private equipment inside the 28°C and 37°C rooms of the facility. If you have special necessities, please contact the facility technical staff.
  • If necessary, reservations can be cancelled no later than 24h prior to the reserved slot.